Profiles Reference
Refer to the following reference information when configuring profiles.
Profile
Number: The id number automatically assigned to the profile.
Rearm Delay: Delay automatic rearming by the number of minutes entered when the user disarms an area outside of a schedule. To disable this feature, enter 0. Range is 0 – 720 minutes.
Output Group: Assign outputs to groups, allowing an entire group of outputs to turn on or off as required. Enter the number of the output group that you want to assign to the profile. To disable this feature, enter 0.
Inactive User Audit Days: Enter a number of days that a user code can remain unused before it is automatically deactivated. To disable this feature, enter 0. Range is 0 – 425 days.
Access Areas: Allow profile members to access selected areas. This setting supersedes Door Access settings in Options.
Arm/Disarm Areas: Allow profile members to arm or disarm selected areas. This setting supersedes Arm and Disarm settings in Options.
Access Schedules: Allow profile members to access and edit a schedule. This setting supersedes Schedules settings in Options.
Private Doors: Allow profile members to access selected private doors. Only doors that have Private Door turned on in Device Setup are displayed in Profiles. When enabled, these permissions allow profile members to access up to 4 private doors.
Options
When enabled in a profile, these permissions allow profile members to perform the following actions:
Arm: Arm the system according to the options configured in Arm/Disarm Areas.
Disarm: Disarm the system according to the options configured in Arm/Disarm Areas.
Alarm Silence: Silence a system alarm.
Sensor Reset: Reset all system sensors. A sensor reset is required for all smoke detectors, flood sensors, and temperature sensors that have triggered an alarm, as well as system restoral after a lockdown is ended. A sensor reset is also required to clear a low battery (LOBAT) message after changing a wireless device’s batteries.
Lockdown: Initiate a lockdown.
Door Lock/Unlock: Lock and unlock doors.
Door Access: Grant temporary door access.
Armed Areas: View armed areas at a keypad.
Outputs On/Off: Turn outputs on or off from the User Menu.
Anti-Passback: Use anti-passback. Profile members are required to properly exit (egress) an area previously accessed. Users cannot re-access the area until they properly exit it. Egress Areas are configured in Device Setup.
Easy Arm/Disarm: Arm or disarm all areas that are assigned to a code automatically.
Use Secondary Language: Display a secondary language.
Card Plus PIN: Use Card Plus Pin. Profile members are required to use two access methods to operate the system from a keypad. The first method must be a credential such as a proximity patch, card, or key fob. The second method must be a PIN number entered at the keypad.
Wi-Fi Setup: View the system’s Wi-Fi settings, connect to available Wi-Fi networks, and use WPS association.
Lockdown Override: End a lockdown and restore the system. Sensor Reset is also required to override a lockdown.
Profiles: Add, change, or delete profiles.
User Codes: Add, change, or delete user codes.
Schedules: Add, edit, or delete schedules.
Extend: Extend a schedule for 2, 4, 6, or 8 hours.
Time: Change the system date and time from the User Menu.
Display Events: View system events.
Service Request: Request a service call from your alarm provider.
Fire Drill: Initiate a fire drill.
Zone Status: View the status of zones.
Bypass Zones: Bypass zones when arming the system.
Zone Monitor: Enable the chime function.
System Status: View the system’s status.
System Test: Initiate a system test from the User Menu.
Technician User: Use the profile for test purposes. A technician user cannot disarm a system that has been armed by a standard user. If the system is armed by a Test User, that person can disarm it.
Dual Authority: Requires two user codes to be entered within 30 seconds of each other at a system keypad to arm or disarm a specific area. Dual Authority must be enabled in Area Information to use this feature.