Authority Levels

When creating a user code, you either select an authority level or assign profiles to the user depending on the system type. For more information about profiles, refer to Profiles.

The following sections include definitions of authority level types, the permissions that each level has, and definitions of each permission:

Authority Level Types

  • Master: The highest authority level. The user is granted all system permissions.

  • Standard: The user is granted all system permissions except administrative permissions.

  • Limited: The user is granted all system permissions except administrative permissions and they cannot bypass zones.

  • Scheduled: The user is granted basic system permissions that don’t include administrative or maintenance permissions.

  • Arm Only: The user can only arm the system.

  • Temporary: The user code expires at the date and time that you specify. Any authority level except Master can be defined as a temporary code.

Permissions by Authority Level

Permission

Definition

Master

Standard

Limited

Scheduled

Arm Only

Arm

Arm the system

X

X

X

X

X

Disarm

Disarm the system

X

X

X

X

Door Access

Grant temporary door access

X

X

X

X

Alarm Silence

Silence a system alarm

X

X

X

X

User Check-in

The system checks in to determine if the user is on the premises

X

X

X

X

Zone Activity Check

Monitor a zone for non-activity. This could be used for a person living alone to detect when they have not moved about to trip a disarmed zone within a programmed period of time. This feature is optional. The Zone Activity Check is disabled when a schedule is entered to allow for sleeping hours and is automatically enabled when an area is disarmed

X

X

X

X

Sensor Reset

Reset all system sensors. A sensor reset is required for all smoke detectors, flood sensors, and temperature sensors that have triggered an alarm, as well as system restoral after a lockdown is ended. A sensor reset is also required to clear a low battery (LOBAT) message after changing a wireless device’s batteries.

X

X

X

X

Display Events

View system events

X

X

X

X

Zone Monitor

Enable the chime function

X

X

X

X

Output On/Off

Turn outputs on or off

X

X

X

System Test

Initiate a system test from the User Menu

X

X

X

Favorites Setup

Configure Z-Wave favorites for the system

X

X

X

Bypass Zones

Bypass zones when arming the system

X

X

Z-Wave Setup

Add, edit, and delete Z-Wave devices like appliances, locks, lights, and thermostats

X

Wi-Fi Setup

View the system’s Wi-Fi settings, connect to available Wi-Fi networks, and use WPS association

X

User Codes

Add, change, or delete user codes

X

Schedules

Add, edit, or delete schedules

X

Extend

Extend a schedule for 2, 4, 6, or 8 hours

X

Set Time

Change the system date and time from the User Menu

X

Service Request

Request a service call from your alarm provider

X